Additional Information:
Product Details:
| Minimum Order Quantity | 3 Piece |
| Machine Type | Automatic |
| Power Source | Solar |
| Brand | POWERAMR |
| Accuracy | High Precision |
| Temperature Range | 0-50 C |
| Operating Temperature | 0-50 C |
| Voltage | 230 VAC |
| Display Type | LED |
| Humidity Range | 0-100 % |
| Measuring Range (Barometric Pressure) | 0 to 1100 hPa |
Additional Information:
.4 Technical Specification
Input type: (Either of below specifications can be used selectively in the one instrument)
Thermocouple: K, S, R, E, J, N, T, B, WRe3-WRe25, WRe5-WRe26.
Resistance temperature detector: Cu50, Pt100
Linear voltage: 05V, 15V, 01V, 0100mV, 020mV, 0~500mV etc.
Linear current (external precise shunt resist needed): 010mA,020mA, 420mA, etc.Extended input (install I4 module in MIO) : 020mA, 420mA or two line transmitter.
Optional: apart from the above-mentioned Input type, an additional type can be provided upon request. (Graduation index is needed)
Instrument Input rangeK(-501300℃), S(-501700℃), R(-501700℃), E(0800℃), J(01000℃), N(01300℃), T(-200~+350℃), B(200~1800℃)Cu50(-50+150℃), Pt100(-200+800℃)
Linear Input: -999030000 defined by user Measurement accuracy : 0.3%FS ± 0.1℃
Resolution : 0.1℃ for K, E, T, N, J, Cu50, Pt100; 1℃ for S,R
Temperature shift : ≤0.015%FS /℃ (typical value is 80ppm/℃)
Sampling period : read A/D converter 8 times per second
Response time : ≤0.5s ( when digital filter parameter FILt=0)
Alarm function : High limit, low limit, deviation high limit and deviation low limit; providing the function of alarm blocking at the beginning of power on.
Control period : 0.24300.0 seconds selectable, and it should be integer times of 0.5 second.
Control mode:On-off control mode (dead band adjustable)Standard PID with auto tuningAI PID with auto tuning, adopting artificial intelligence algorithm.
Output mode (modularized)
Relay output (NO+NC): 250VAC/1A or 30VDC/1ATRIAC no contact discrete output (NO or NC): 100240VAC/0.2A (continuous), 2A (20mS instantaneous, repeat period≥5s)SSR Voltage output: 12VDC/30mA (used to drive SSR).
Thyristor zero crossing trigger output: Can trigger TRIAC of 5500A, a pair of inverse paralleled SCRs or SCR power module.Linear current output: 020mA, 420mA can scaling by user. (Output voltage : X3≥10.5V; X5≥7V maximum load resistor 500ohm, output precision 0.2%FS) Electromagnetic compatibility (EMC): ±4KV/5KHz according to IEC61000-4-4; 4KV according to
2. Display and Operation 2.1 Front Panel Description Upper display window: Displays PV, parameter code, etc. Lower display window: Displays SV, parameter value, or alarm message Setup key: For accessing parameter table and conforming parameter modification.
Data shift key, start auto tuning Data decrease key, and also run switch Data increase key, and also stop key LED indicator: “MAN” led is non-applicable for AI-526 series. “RUN” led on, it mean AI-518P running program. MIO, OP1, OP2, AL1, AL2, AU1 and AU2 indicate I/O operation of the corresponding module. For example, when COMM led is lighting means that the instrument is communicating with computer.AI
Additional Information:
Additional Information:
Additional Information:
| Cat. Ref. No. | Wattage |
| KI 203 080 R | 80 |
| KI 203 100 R | 100 |
Additional Information:
Additional Information:
Specifications:
Cat. Ref. No.WattageKI 501 080 T80KI 501 100 T100
Material:
Cold rolled plate body
Powder coated
Aluminium reflector
Plastic Grill, Beautiful appearance
Application Areas:
Home/Showrooms/Offices
Multiplexes/Cinema Halls
Supermarket/Hotels/Restaurants
Public Halls/Shopping Malls & Petrol pump
Additional Information:
Product Details:
| Physical State | Powder |
| Packaging Type | 200ML |
| Packaging Size | 200ML |
Additional Information: